Certificates and test reports
Want to know what you're getting? Here you'll find every certificate, test report, and measurement report for each product. Each document states who tested it, when, and with what equipment, so you can compare our figures fairly.
What has been tested
At a glance, see which tests and measurements have been conducted for each product. You’ll find the documents further down.
| Product | CE-LVD | CE-EMC | FCC | RoHS | Light measurement | EMF measurement |
|---|---|---|---|---|---|---|
| ATP Pro | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| ATP Pure | ✓ | ✓ | ✓ | ✓ | ✓in our factory | ✓in our factory |
| LED Mask | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
01
ATP Pro
Eight wavelengths, touchscreen, and adjustable intensity. Tested by an independent laboratory and measured by us for light intensity and EMF.
- Laboratory
- Shenzhen ZKT Technology
- Test date
- August 2025
- Models
- ATP Pro 350, 700, 1500
- On behalf of
- Advanced Health Solutions B.V.
Certifications
The ATP Pro is our own design. That’s why Panacea is listed as both the applicant and manufacturer in every report, tested by an independent laboratory.
CE-EMC test reportPASS
Electromagnetic compatibility, EMC Directive 2014/30/EU. Emissions and immunity according to EN IEC 55015, EN IEC 61547, EN IEC 61000-3-2 and EN 61000-3-3.
CE-LVD test report
Electrical safety, Low Voltage Directive 2014/35/EU. According to EN 60598-2-4 and EN IEC 60598-1: construction, insulation, protection against electric shock, and heating.
FCC test reportPASS
Radiated emissions according to FCC Part 15 B and ANSI C63.4:2014, the U.S. requirement for electronic devices.
RoHS test reportPASS
Hazardous substances, Directive 2011/65/EU with (EU) 2015/863. Tested for lead, cadmium, mercury, hexavalent chromium, PBBs, PBDEs, and four phthalates.
Light intensity (irradiance) ATP Pro 1500
Measured by Panacea with an Everfine handheld spectroradiometer (380 to 1050 nm), at the center of the panel, at five distances and in three settings. The report includes a display photo of each measurement. Nothing was added or extrapolated.
| Mode | Contact | 7.5 cm | 15 cm | 20 cm | 30 cm |
|---|---|---|---|---|---|
| All wavelengths on | 118,9 | 92,8 | 83,1 | 47,2 | 68,5 |
| Red only (590, 630, 660 nm) | 289,6 | 138,7 | 67,4 | 45,0 | 36,6 |
| Near-infrared only (810 to 1072 nm) | 267,3 | 146,8 | 74,6 | 20,4 | 30,5 |
All values in mW/cm², measured with a spectroradiometer. 83.1 at 15 cm is the average of 78.5 and 87.6. At 15 cm, with all wavelengths on, you get 10 J/cm² in about 2 minutes and 20 J/cm² in about 4 minutes. 1060 and 1072 nm are outside the meter's range, so the actual total irradiance is likely slightly higher. The measurements at 20 and 30 cm were done manually and are less consistent.
Light intensity measurement report ATP Pro 1500
Spectrometer of solarmeter: not the same
Light intensity can be measured with two types of meters, and they give very different readings for the same panel. So never compare a solar meter reading with a spectrometer reading. Below is the ATP Pro 1500, measured with both.
Measures by wavelength
83mW/cm²ATP Pro 1500, center of the panel, 15 cm, all wavelengths on
Splits the light by wavelength and only adds up what actually comes out of the panel. This is the method used by laboratories and the reading you can compare with a lab report.
Designed for sunlight
216mW/cm²same panel, same distance
A solar meter is calibrated for the broad spectrum of sunlight and reads the narrow peaks from red and near-infrared LEDs 2 to 3 times too high. Most of the figures between 150 and 250 mW/cm² you see from brands come from a meter like that.
Electromagnetic fields (EMF) ATP Pro
Measured by Panacea with a TriField TF2 broadband EMF meter, on two ATP Pro panels at maximum power, directly in front of the LED surface, at a grounded outlet.
| Quantity | Measured | European limit | Below the limit |
|---|---|---|---|
| Electric field | 44 to 55 V/m | 5,000 V/m | approx. 100x lower |
| Magnetic field | 1.0 to 1.3 mG (0.10 to 0.13 µT) | 1,000 mG (100 µT) | over 750x lower |
| Radio frequency | 0.054 to 0.070 mW/m² | 2,000 to 10,000 mW/m² | over 25,000x lower |
Limits (reference levels) for the general public according to Recommendation 1999/519/EC and ICNIRP. Without grounding, the electric field was about twice as high (89 to 106 V/m), still well below the limit.
EMF measurement report ATP Pro
02
ATP Pure
Four wavelengths and four-button control. The same safety and certification requirements as the ATP Pro.
- Laboratory
- Shenzhen ZKT Technology
- Test date
- September 2026
- Models
- ATP Pure 300, 700, 1500
- On behalf of
- Advanced Health Solutions B.V.
Certifications
The ATP Pure is also our own design, with Panacea listed as both applicant and manufacturer in every report. Each test report comes with a certificate.
CE-EMC test reportPASS
Electromagnetic compatibility, EMC Directive 2014/30/EU. Emissions and immunity according to EN IEC 55015, EN IEC 61547, EN IEC 61000-3-2, EN 61000-3-3, and the immunity tests in the EN 61000-4 series.
CE-LVD test report
Electrical safety, Low Voltage Directive 2014/35/EU. In accordance with EN 60598-2-4:2018 and EN IEC 60598-1:2024+A11:2024, the standards for portable luminaires.
FCC test reportPASS
Radio interference according to FCC Part 15 B and ANSI C63.4:2014.
RoHS test reportPASS
Hazardous substances, Directive 2011/65/EU with (EU) 2015/863. Tested for lead, cadmium, mercury, hexavalent chromium, PBBs, PBDEs, and four phthalates.
ATP Pure light intensity
Measured in our factory using a solar meter (TES 1333) and a spectrometer (HA350FRW), at the center of the panel. We always list both values so you can compare them fairly.
| Distance | Solarmeter | Spectrometer |
|---|---|---|
| 7.5 cm | 202 mW/cm² | 104 mW/cm² |
| 15 cm | 170 mW/cm² | 92 mW/cm² |
Values as measured at our factory on the ATP Pure 700. Once the first panels arrive in the Netherlands, we will measure them ourselves with our spectroradiometer and publish the report here.
03
LED Mask
Light output per program and electromagnetic fields at maximum intensity, measured where the light reaches the skin.
- Light measurement
- in our factory, spectral irradiance meter
- EMF measurement
- Panacea, TriField TF2
- Report
- AUR-2026-001
- Date
- September 2026
Light output and EMF per program
Light measurement in our factory using a Hopoocolor OHSP-350IRS spectral irradiance meter (blue program with an HP350 spectrometer), sensor against the inner surface of the LED. EMF measurement by Panacea using a TriField TF2 against the inside of the mask.
| Program | Wavelengths (nm) | Irradiance at 100% (mW/cm²) | Weighted magnetic field (mG) |
|---|---|---|---|
| Collagen Boost | 633 | 33,9 | 15,5 |
| Skin Quality | 590 + 633 | 33,7 | 13,7 |
| Anti-Aging | 633 + 850/1072 | 37,1 | 15,1 |
| Total Care | 590 + 633 + 850/1072 | 36,3 | 15,9 |
| Anti-Acne | 415 | 18,9 | 7,6 |
| Redness Relief | 590 | 6,6 | 5,5 |
The décolleté section delivered 41.1 to 43.8 mW/cm² with a higher proportion of near-infrared light. The mask runs on the controller's battery and is not connected to the mains during use. Even after frequency weighting, all EMF values are at least 50 times below the European limits.
Measurement report for the LED Mask with décolleté section
What the standards mean
CE-LVD (2014/35/EU)
Electrical safety: design, insulation, and heat generation are safe at 100 to 240 volts. The panels were tested according to EN 60598-2-4 and EN IEC 60598-1, the standards for luminaires.
CE-EMC (2014/30/EU)
The device does not interfere with other devices and is itself resistant to external interference. Note: EMC concerns interference between devices, while EMF concerns your body's exposure. There is a separate EMF report for that.
FCC Part 15 B
The American requirement for radio interference from electronic devices.
RoHS (2011/65/EU)
Restriction of hazardous substances such as lead, mercury, cadmium, and certain plasticizers in electronics.
Irradiance (mW/cm²)
The amount of light power per square centimeter of skin. Together with the time, this determines the dose in J/cm² (irradiance x seconds, divided by 1000).
Alle downloads
Elk document op deze pagina, per product, vrij te downloaden.
Find the panel that fits you
ATP Pro and ATP Pure are both CE-, FCC-, and RoHS-tested. Try it at home for 180 days.
Measured, not promised
The light from the Panacea LED Mask was measured with a spectrometer at six points directly on the LEDs: three on the mask and three on the neck section. The results are shown below, along with photos of the meter.
- Light intensity
- 33,5mW/cm²
- averaged across six measurement points
- Red light
- 626nm
- measured peak, nominal 633 nm
- Near-infrared
- 10mW/cm²
- alongside 23 mW/cm² of red light
Range of the six measurements: 30.5 to 37.1 mW/cm²
-
Neck area: 37.1 mW/cm² -
Mask: 33.8 mW/cm² -
Mask: 31.0 mW/cm²
View all six measurements
| Meetpunt | Totaal (mW/cm²) | Rood (mW/cm²) | Nabij-infrarood (mW/cm²) | Piek rood |
|---|---|---|---|---|
| Neck 1 | 33,9 | 21,2 | 12,2 | 625,6 nm |
| Neck 2 | 34,5 | 24,7 | 9,4 | 626,9 nm |
| Neck 3 | 37,1 | 24,9 | 11,9 | 625,6 nm |
| Face 1 | 33,8 | 24,6 | 8,7 | 626,7 nm |
| Face 2 | 31,0 | 22,1 | 8,5 | 626,5 nm |
| Face 3 | 30,5 | 20,8 | 9,3 | 627,8 nm |
Measured with an OHSP-350IRS spectrometer, with the sensor directly on the LEDs. This is appropriate for a mask because it rests against your skin. The values apply to the measured spots. Readings may vary slightly between LEDs and from one unit to another.
Questions about certificates and measurements
The questions we get most often about our certificates, test reports, and measurements.
Certificates
Are the Panacea panels CE-certified?
Yes. Both the ATP Pro series (350, 700, and 1500) and the ATP Pure series (300, 700, and 1500) have been tested under the Low Voltage Directive (CE-LVD) and the EMC Directive (CE-EMC), as well as for FCC and RoHS compliance. All reports are available on this page for free download.
Are the certificates in the name of Panacea?
Yes. Advanced Health Solutions B.V., the company behind Panacea Light Therapy, is listed in the ZKT reports as both the applicant and the manufacturer. This is possible because the panels are our own design, not a standard model that simply has a brand name added to it.
Can I download the documents?
Yes, everything on this page is free to download. If you’re missing a document, email info@panacearedlight.com.
Measurements
Who performed the measurements?
That is stated on every document. The CE, FCC, and RoHS tests were conducted by an independent laboratory (Shenzhen ZKT Technology). The light measurement of the ATP Pro 1500 and the EMF measurements were conducted in-house by Panacea, with photos of the display for each measurement point. The light measurements of the LED Mask and the ATP Pure series were conducted at our factory.
Why are there two different numbers for the light intensity?
Because there are two types of meters that measure very differently. A solar meter is designed for sunlight and reads LED light 2 to 3 times too high. A spectroradiometer measures what actually comes from the panel at each wavelength. The ATP Pro 1500 measures 216 mW/cm² at 15 cm with a solar meter and 83 mW/cm² with a spectroradiometer. So always compare values measured with the same type of meter.
Are the panels EMF-free?
No mains-powered device is entirely free of these fields. The electric field of the ATP Pro at full power is about 100 times below the European limit, and the magnetic field is more than 750 times below it. Use the panel with a grounded outlet; this cuts the electric field in half.
Are you missing a document?
Email us at info@panacearedlight.com or message us at +31 6 82056852. We'd be happy to send it to you.