Transparency

Certificates and test reports

Want to know what you're getting? Here you'll find every certificate, test report, and measurement report for each product. Each document states who tested it, when, and with what equipment, so you can compare our figures fairly.

CE, FCC, RoHSCustom design, not a standard panel with just our logo on it. That’s why the certificates are in the name of Panacea as the manufacturer.
83 mW/cm²Light intensity of ATP Pro 1500 at 15 cm, measured with a spectroradiometer, all wavelengths on. With a solar meter, which is how most brands measure, it is 216 mW/cm².
100x warehouse saleThe electric field of the ATP Pro at full power is approximately 100 times lower than the European limit.

What has been tested

At a glance, see which tests and measurements have been conducted for each product. You’ll find the documents further down.

ProductCE-LVDCE-EMCFCCRoHSLight measurementEMF measurement
ATP Pro✓✓✓✓✓✓
ATP Pure✓✓✓✓✓in our factory✓in our factory
LED Mask✓✓✓✓✓✓
ATP Pro01
Panels · 350, 700 and 1500

ATP Pro

Eight wavelengths, touchscreen, and adjustable intensity. Tested by an independent laboratory and measured by us for light intensity and EMF.

Laboratory
Shenzhen ZKT Technology
Test date
August 2025
Models
ATP Pro 350, 700, 1500
On behalf of
Advanced Health Solutions B.V.
CE-EMCCE-LVDFCCRoHSLight measurementEMF measurement

Certifications

The ATP Pro is our own design. That’s why Panacea is listed as both the applicant and manufacturer in every report, tested by an independent laboratory.

EMC Directive 2014/30/EU

CE-EMC test reportPASS

Electromagnetic compatibility, EMC Directive 2014/30/EU. Emissions and immunity according to EN IEC 55015, EN IEC 61547, EN IEC 61000-3-2 and EN 61000-3-3.

Report ZKT-25081119334E, August 19, 2025. Models: ATP Pro 1500, 700 and 350.

Low Voltage Directive 2014/35/EU

CE-LVD test report

Electrical safety, Low Voltage Directive 2014/35/EU. According to EN 60598-2-4 and EN IEC 60598-1: construction, insulation, protection against electric shock, and heating.

ZKT-25081119333S report, August 18, 2025. Models: ATP Pro 1500, 700, and 350.

FCC Part 15 B

FCC test reportPASS

Radiated emissions according to FCC Part 15 B and ANSI C63.4:2014, the U.S. requirement for electronic devices.

Report ZKT-25081119335E, August 19, 2025. Models: ATP Pro 1500, 700 and 350.

RoHS Directive 2011/65/EU

RoHS test reportPASS

Hazardous substances, Directive 2011/65/EU with (EU) 2015/863. Tested for lead, cadmium, mercury, hexavalent chromium, PBBs, PBDEs, and four phthalates.

Report ZKT-25081119336R, August 21, 2025. Models: ATP Pro 1500, 700, and 350.

Light intensity (irradiance) ATP Pro 1500

Measured by Panacea with an Everfine handheld spectroradiometer (380 to 1050 nm), at the center of the panel, at five distances and in three settings. The report includes a display photo of each measurement. Nothing was added or extrapolated.

ModeContact7.5 cm15 cm20 cm30 cm
All wavelengths on118,992,883,147,268,5
Red only (590, 630, 660 nm)289,6138,767,445,036,6
Near-infrared only (810 to 1072 nm)267,3146,874,620,430,5

All values in mW/cm², measured with a spectroradiometer. 83.1 at 15 cm is the average of 78.5 and 87.6. At 15 cm, with all wavelengths on, you get 10 J/cm² in about 2 minutes and 20 J/cm² in about 4 minutes. 1060 and 1072 nm are outside the meter's range, so the actual total irradiance is likely slightly higher. The measurements at 20 and 30 cm were done manually and are less consistent.

Own measurement, spectroradiometer

Light intensity measurement report ATP Pro 1500

Report IRR-ATP1500, revision 2.0, October 2026. In-house measurement by Panacea, 16 measurement points with display photos.

Spectrometer of solarmeter: not the same

Light intensity can be measured with two types of meters, and they give very different readings for the same panel. So never compare a solar meter reading with a spectrometer reading. Below is the ATP Pro 1500, measured with both.

Spectroradiometer
Measures by wavelength
83mW/cm²

ATP Pro 1500, center of the panel, 15 cm, all wavelengths on

Splits the light by wavelength and only adds up what actually comes out of the panel. This is the method used by laboratories and the reading you can compare with a lab report.

Solar meter
Designed for sunlight
216mW/cm²

same panel, same distance

A solar meter is calibrated for the broad spectrum of sunlight and reads the narrow peaks from red and near-infrared LEDs 2 to 3 times too high. Most of the figures between 150 and 250 mW/cm² you see from brands come from a meter like that.

How to make a fair comparison. For each figure, check which meter was used, at what distance, and which wavelengths were on. If a brand lists a solar meter reading, compare it with our 216 mW/cm². If a brand lists a spectrometer reading or a lab report, compare it with our 83 mW/cm².

Electromagnetic fields (EMF) ATP Pro

Measured by Panacea with a TriField TF2 broadband EMF meter, on two ATP Pro panels at maximum power, directly in front of the LED surface, at a grounded outlet.

QuantityMeasuredEuropean limitBelow the limit
Electric field44 to 55 V/m5,000 V/mapprox. 100x lower
Magnetic field1.0 to 1.3 mG (0.10 to 0.13 µT)1,000 mG (100 µT)over 750x lower
Radio frequency0.054 to 0.070 mW/m²2,000 to 10,000 mW/m²over 25,000x lower

Limits (reference levels) for the general public according to Recommendation 1999/519/EC and ICNIRP. Without grounding, the electric field was about twice as high (89 to 106 V/m), still well below the limit.

Why we don't claim "0 EMF." Every mains-powered device has a small field. Simple meters measure up to about 1 kHz and showed 0 V/m here; our broadband meter, which measures up to 100 kHz, does detect a field. We publish the actual values.
Own measurement, TriField TF2

EMF measurement report ATP Pro

EMF report-2026-001, version 1.0, September 2026. In-house measurement by Panacea with display photos for each measurement point.

ATP Pure02
Panels · 300, 700 and 1500

ATP Pure

Four wavelengths and four-button control. The same safety and certification requirements as the ATP Pro.

Laboratory
Shenzhen ZKT Technology
Test date
September 2026
Models
ATP Pure 300, 700, 1500
On behalf of
Advanced Health Solutions B.V.
CE-EMCCE-LVDFCCRoHS

Certifications

The ATP Pure is also our own design, with Panacea listed as both applicant and manufacturer in every report. Each test report comes with a certificate.

EMC Directive 2014/30/EU

CE-EMC test reportPASS

Electromagnetic compatibility, EMC Directive 2014/30/EU. Emissions and immunity according to EN IEC 55015, EN IEC 61547, EN IEC 61000-3-2, EN 61000-3-3, and the immunity tests in the EN 61000-4 series.

Report ZKT-2609150906E and certificate ZKT-2609150906C, September 20, 2026. Models: ATP Pure 1500, 700, and 300.

Low Voltage Directive 2014/35/EU

CE-LVD test report

Electrical safety, Low Voltage Directive 2014/35/EU. In accordance with EN 60598-2-4:2018 and EN IEC 60598-1:2024+A11:2024, the standards for portable luminaires.

Report ZKT-2609150907S and certificate ZKT-2609150907C, September 20, 2026. Models: ATP Pure 1500, 700, and 300.

FCC Part 15 B

FCC test reportPASS

Radio interference according to FCC Part 15 B and ANSI C63.4:2014.

Report ZKT-2609150908E and statement ZKT-2609150908C, September 20, 2026. Models: ATP Pure 1500, 700, and 300.

RoHS Directive 2011/65/EU

RoHS test reportPASS

Hazardous substances, Directive 2011/65/EU with (EU) 2015/863. Tested for lead, cadmium, mercury, hexavalent chromium, PBBs, PBDEs, and four phthalates.

Report ZKT-2609150909R and certificate ZKT-2609150909C, September 23, 2026. Models: ATP Pure 1500, 700, and 300.

ATP Pure light intensity

Measured in our factory using a solar meter (TES 1333) and a spectrometer (HA350FRW), at the center of the panel. We always list both values so you can compare them fairly.

DistanceSolarmeterSpectrometer
7.5 cm202 mW/cm²104 mW/cm²
15 cm170 mW/cm²92 mW/cm²

Values as measured at our factory on the ATP Pure 700. Once the first panels arrive in the Netherlands, we will measure them ourselves with our spectroradiometer and publish the report here.

LED Mask03
Mask · with neck and décolleté

LED Mask

Light output per program and electromagnetic fields at maximum intensity, measured where the light reaches the skin.

Light measurement
in our factory, spectral irradiance meter
EMF measurement
Panacea, TriField TF2
Report
AUR-2026-001
Date
September 2026
CEFCCRoHSlight measurementEMF measurement

Light output and EMF per program

Light measurement in our factory using a Hopoocolor OHSP-350IRS spectral irradiance meter (blue program with an HP350 spectrometer), sensor against the inner surface of the LED. EMF measurement by Panacea using a TriField TF2 against the inside of the mask.

ProgramWavelengths (nm)Irradiance at 100% (mW/cm²)Weighted magnetic field (mG)
Collagen Boost63333,915,5
Skin Quality590 + 63333,713,7
Anti-Aging633 + 850/107237,115,1
Total Care590 + 633 + 850/107236,315,9
Anti-Acne41518,97,6
Redness Relief5906,65,5

The décolleté section delivered 41.1 to 43.8 mW/cm² with a higher proportion of near-infrared light. The mask runs on the controller's battery and is not connected to the mains during use. Even after frequency weighting, all EMF values are at least 50 times below the European limits.

Light and EMF per program

Measurement report for the LED Mask with décolleté section

Report AUR-2026-001, version 1.0, September 2026. Light measurement at our factory, EMF measurement by Panacea, with display photos.

Uitleg

What the standards mean

CE-LVD (2014/35/EU)

Electrical safety: design, insulation, and heat generation are safe at 100 to 240 volts. The panels were tested according to EN 60598-2-4 and EN IEC 60598-1, the standards for luminaires.

CE-EMC (2014/30/EU)

The device does not interfere with other devices and is itself resistant to external interference. Note: EMC concerns interference between devices, while EMF concerns your body's exposure. There is a separate EMF report for that.

FCC Part 15 B

The American requirement for radio interference from electronic devices.

RoHS (2011/65/EU)

Restriction of hazardous substances such as lead, mercury, cadmium, and certain plasticizers in electronics.

Irradiance (mW/cm²)

The amount of light power per square centimeter of skin. Together with the time, this determines the dose in J/cm² (irradiance x seconds, divided by 1000).

Overzicht

Alle downloads

Elk document op deze pagina, per product, vrij te downloaden.

ATP Pro

  • CE-EMC test report
    PDF
  • CE-LVD test report
    PDF
  • FCC test report
    PDF
  • RoHS test report
    PDF
  • Light intensity measurement report ATP Pro 1500NL
    PDF
  • Light intensity measurement report ATP Pro 1500EN
    PDF
  • EMF measurement report ATP ProNL
    PDF
  • EMF measurement report ATP ProEN
    PDF

ATP Pure

  • CE-EMC test report
    PDF
  • CE-EMC test report
    PDF
  • CE-LVD test report
    PDF
  • CE-LVD test report
    PDF
  • FCC test report
    PDF
  • FCC test report
    PDF
  • RoHS test report
    PDF
  • RoHS test report
    PDF

LED Mask

  • Measurement report for the LED Mask with décolleté section
    PDF

Find the panel that fits you

ATP Pro and ATP Pure are both CE-, FCC-, and RoHS-tested. Try it at home for 180 days.

View the panels
Light measurement Panacea LED Mask

Measured, not promised

The light from the Panacea LED Mask was measured with a spectrometer at six points directly on the LEDs: three on the mask and three on the neck section. The results are shown below, along with photos of the meter.

Light intensity
33,5mW/cm²
averaged across six measurement points
Red light
626nm
measured peak, nominal 633 nm
Near-infrared
10mW/cm²
alongside 23 mW/cm² of red light

Range of the six measurements: 30.5 to 37.1 mW/cm²

  • Neck area: 37.1 mW/cm²
    Neck area: 37.1 mW/cm²
  • Mask: 33.8 mW/cm²
    Mask: 33.8 mW/cm²
  • Mask: 31.0 mW/cm²
    Mask: 31.0 mW/cm²
View all six measurements
Meetpunt Totaal (mW/cm²) Rood (mW/cm²) Nabij-infrarood (mW/cm²) Piek rood
Neck 1 33,9 21,2 12,2 625,6 nm
Neck 2 34,5 24,7 9,4 626,9 nm
Neck 3 37,1 24,9 11,9 625,6 nm
Face 1 33,8 24,6 8,7 626,7 nm
Face 2 31,0 22,1 8,5 626,5 nm
Face 3 30,5 20,8 9,3 627,8 nm

Measured with an OHSP-350IRS spectrometer, with the sensor directly on the LEDs. This is appropriate for a mask because it rests against your skin. The values apply to the measured spots. Readings may vary slightly between LEDs and from one unit to another.

Frequently Asked Questions

Questions about certificates and measurements

The questions we get most often about our certificates, test reports, and measurements.

  1. 01Certificates
  2. 02Measurements

Certificates

Are the Panacea panels CE-certified?

Yes. Both the ATP Pro series (350, 700, and 1500) and the ATP Pure series (300, 700, and 1500) have been tested under the Low Voltage Directive (CE-LVD) and the EMC Directive (CE-EMC), as well as for FCC and RoHS compliance. All reports are available on this page for free download.

Are the certificates in the name of Panacea?

Yes. Advanced Health Solutions B.V., the company behind Panacea Light Therapy, is listed in the ZKT reports as both the applicant and the manufacturer. This is possible because the panels are our own design, not a standard model that simply has a brand name added to it.

Can I download the documents?

Yes, everything on this page is free to download. If you’re missing a document, email info@panacearedlight.com.

Measurements

Who performed the measurements?

That is stated on every document. The CE, FCC, and RoHS tests were conducted by an independent laboratory (Shenzhen ZKT Technology). The light measurement of the ATP Pro 1500 and the EMF measurements were conducted in-house by Panacea, with photos of the display for each measurement point. The light measurements of the LED Mask and the ATP Pure series were conducted at our factory.

Why are there two different numbers for the light intensity?

Because there are two types of meters that measure very differently. A solar meter is designed for sunlight and reads LED light 2 to 3 times too high. A spectroradiometer measures what actually comes from the panel at each wavelength. The ATP Pro 1500 measures 216 mW/cm² at 15 cm with a solar meter and 83 mW/cm² with a spectroradiometer. So always compare values measured with the same type of meter.

Are the panels EMF-free?

No mains-powered device is entirely free of these fields. The electric field of the ATP Pro at full power is about 100 times below the European limit, and the magnetic field is more than 750 times below it. Use the panel with a grounded outlet; this cuts the electric field in half.

Are you missing a document?

Email us at info@panacearedlight.com or message us at +31 6 82056852. We'd be happy to send it to you.